I'm using WinCE 7 Visual Studio 2008 and writing a driver code for ALS (MAX44009). I have written the following code for reading the interrupt status register and displaying messages when the interrupt has occurs. But, it works randomly for a few times only. For eg., when I close the sensor with my hand, I get the messages only few times, and then, it doesn't go into the data==1
condition even when it has to interrupt and continues to loop. The threshold timer is 0. The AlsRegRead
function does an I2CRead. pAlsDrvInfo
is the driver context. ADD_ALS_INT_STATUS
is 0
. DumpAlsRegistry
function will print the content of all the registers except register 0x0
.
while(1)
{
AlsRegRead(pAlsDrvInfo, ADD_ALS_INT_STATUS, &data, sizeof(UINT8));
if (data == 1)
{
DumpAlsRegistry(pAlsDrvInfo);
RETAILMSG(1,(L"Interrupt Received...\r\n"));
}
}
Please guide me where I'm making mistake.
I have found the reason behind this. Two issues had been behind this and both of them are equally important.
1) The sensor had been in a partially damaged state.
2) It requires some delay. So, I added Sleep(1000)
at the start of the loop.
while(1)
{
Sleep(1000);
AlsRegRead(pAlsDrvInfo, ADD_ALS_INT_STATUS, &data, sizeof(UINT8));
if (data == 1)
{
DumpAlsRegistry(pAlsDrvInfo);
RETAILMSG(1,(L"Interrupt Received...\r\n"));
}
}