I managed to write a plasmoid using Python with a configuration dialog where one can select a file. I also managed to read out the selected value.
But how can I make the selection persistent? I'm pretty sure that there's some KDE/Qt predefined function or way to do it, but I didn't find documentation about this.
Here's my code (which can be started with plasma-windowed):
metadata.desktop:
[Desktop Entry]
Encoding=UTF-8
Name=Config Test
Type=Service
ServiceTypes=Plasma/Applet
X-Plasma-API=python
X-Plasma-MainScript=code/main.py
contents/code/main.py:
# -*- coding: utf-8 -*-
from PyQt4 import QtCore
from PyKDE4.plasma import Plasma
from PyKDE4 import plasmascript
class configTest(plasmascript.Applet):
def __init__(self, parent, args = None):
plasmascript.Applet.__init__(self, parent)
def init(self):
self.setAspectRatioMode(Plasma.IgnoreAspectRatio)
def paintInterface(self, painter, option, rect):
painter.save()
painter.setPen(QtCore.Qt.black)
painter.drawText(rect, QtCore.Qt.AlignLeft, str(self.config('main').readEntry('testEntry')))
painter.restore()
def CreateApplet(parent):
return configTest(parent)
contents/ui/config.ui:
<?xml version="1.0" encoding="UTF-8"?>
<ui version="4.0">
<class>Config</class>
<widget class="QWidget" name="verticalLayoutWidget">
<layout class="QVBoxLayout" name="verticalLayout">
<item>
<widget class="KUrlRequester" name="kcfg_testEntry"/>
</item>
</layout>
</widget>
<resources/>
<connections/>
</ui>
contents/config/main.xml:
<?xml version="1.0" encoding="UTF-8"?>
<kcfg xmlns="http://www.kde.org/standards/kcfg/1.0"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xsi:schemaLocation="http://www.kde.org/standards/kcfg/1.0
http://www.kde.org/standards/kcfg/1.0/kcfg.xsd">
<kcfgfile name="configTestrc"/>
<include>kglobalsettings.h</include>
<group name="main">
<entry name="testEntry" type="Url"></entry>
</group>
</kcfg>
Thanks in advance for all help!
Finally, I can answer this question myself. The above code does actually work and the configuration is stored automagically – as soon as the package has been installed (via plasmapkg) and started by the plasma desktop tools.
This is not the case when the plasmoid is started via plasma-windowed.