is it possible to use one GCLK for more peripherals?
The ATSAMD09C13 have six GCLK Generators but this isn´t enougth.
This example works:
GCLK->CLKCTRL.reg = GCLK_CLKCTRL_ID(SERCOM0_GCLK_ID_CORE) |
GCLK_CLKCTRL_CLKEN | GCLK_CLKCTRL_GEN(0);
This example, with two ID´s doesn´t work:
GCLK->CLKCTRL.reg = GCLK_CLKCTRL_ID(SERCOM0_GCLK_ID_CORE) | GCLK_CLKCTRL_ID(GCLK_CLKCTRL_ID_WDT) |
GCLK_CLKCTRL_CLKEN | GCLK_CLKCTRL_GEN(0);
Exist a way to solve this or is this not possible?
In register GCLK_CLKCTRL
the field ID
is not a bit mask but holds the number of the peripheral you want to configure.
you cannot combine them by OR
ing multiple IDs.
Instead configure each device separately:
Here is some code generated by Harmony3 to provide GCLK0
/ GCLK1
to multiple devices:
/* Selection of the Generator and write Lock for WDT */
GCLK_REGS->GCLK_CLKCTRL = GCLK_CLKCTRL_ID(3) | GCLK_CLKCTRL_GEN(0x0) | GCLK_CLKCTRL_CLKEN_Msk;
/* Selection of the Generator and write Lock for EIC */
GCLK_REGS->GCLK_CLKCTRL = GCLK_CLKCTRL_ID(5) | GCLK_CLKCTRL_GEN(0x1) | GCLK_CLKCTRL_CLKEN_Msk;
/* Selection of the Generator and write Lock for SERCOM0_CORE */
GCLK_REGS->GCLK_CLKCTRL = GCLK_CLKCTRL_ID(14) | GCLK_CLKCTRL_GEN(0x1) | GCLK_CLKCTRL_CLKEN_Msk;
/* Selection of the Generator and write Lock for TC1 TC2 */
GCLK_REGS->GCLK_CLKCTRL = GCLK_CLKCTRL_ID(18) | GCLK_CLKCTRL_GEN(0x1) | GCLK_CLKCTRL_CLKEN_Msk;
/* Selection of the Generator and write Lock for ADC */
GCLK_REGS->GCLK_CLKCTRL = GCLK_CLKCTRL_ID(19) | GCLK_CLKCTRL_GEN(0x0) | GCLK_CLKCTRL_CLKEN_Msk;