assemblyreverse-engineeringidaollydbg

Differences in OllyDbg and IDA PRO for MOVSX EDX, BYTE PTR [ESP+ECX+8] command


While disassembling the same program using OllyDbg and IDA PRO I have one line of code disassembled in different ways.

OllyDBG:

    MOVSX EDX,BYTE PTR [ESP+ECX+8]

IDA:

    MOVSX EDX, [ESP+ECX+68h+String]

Can someone explain what does IDA PRO mean here? I am frustrated by 68h+String part here. Can I assume that 68h+String always means BYTE PTR?


Solution

  • ida should have declared STRING to be a LOCAL variable with a value of -60h look at the start of function / procedure

    ( 68 + STRING ) == ( 68 + (- 60 ) ) == (68-60) == 8 it is same as what ollydbg shows .

    IDA's disassembly syntax tends to be confusing

    as an example ollydbg will show

    00405712     8B4424 30       MOV     EAX, DWORD PTR SS:[ESP+30]
    

    while ida would show

    text:00405712                 mov     eax, [esp+1Ch+arg_4]
    

    because at the start of function ida has defined arg_4 as

    .text:004056E0 arg_4           = dword ptr  14h
    

    that is

    14h + 1ch == 30h
    

    if you do not prefer ida syntax but would like to see a straight [esp+30]

    you can run this script

    shift +f2 paste and press ok 
    

    beware all ida idc functions are too slow for any mass operations instead of MaxEA() curtail it to some smaller block for a faster result in the snippet below

    auto i;
    
    for (  i = MinEA() ; i < MaxEA() ; i = NextHead(i, MaxEA()) )
    {
        OpHex(i,-1);
    }